    Lab Grade Double Junction pH Electrode with Extended Cable

  • $0.00
  • Add To Cart

    DESCRIPTION
    The MA911B/2 probe is lab grade, gel-filled pH probe for use with Milwaukee Monitors and Controllers.
    DESIGN FEATURES
    Top features include:
    DOUBLE JUNCTION
    The double junction design reduces the risk of clogging.
    SPHERICAL GLASS TIP
    The spherical glass tip provides the largest possible surface area for faster results.
    RESIN BODY
    The resin body is tough to withstand accidental knocks and also protects the glass sensing bulb.
    EXTENDED CABLE
    Offers a 6.6 feet cable for increased flexibility in measuring.
    USE AND CARE
    pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.
    SENSING BULB
    The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.
    REFERENCE JUNCTION
    The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and the reference. If the junction hole gets clogged, the pH probe will no longer function.
    You can extend the life of your pH electrode in the following ways.
    STORAGE
    The pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.
    Storing in pH probe storage solution or pH calibration buffers will help address both these issues. Do not store in tap water and DI water. This will damage the sensitivity of the probe.
    The best way to store the probe is with the probe's cap filled with storage solution or calibration buffer and the cap tightened to prevent leakage. It is also recommended to store the electrode upright to further reduce the potential for leakage.
    CLEANING
    Residue from the sample can impact the sensitivity of the sensing bulb and block the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in a cleaning solution.
  • Hotline Whatsapp

    Do you have a query click whatsapp button below to chat with a representative

    Whatsapp
  • Online Payments

    Currently payment is on delivery. We working on intergrating wide range of online payments

  • Delivered to you

    We currently offering free delivery in Harare CBD and sorrounding areas

    Who we are

    Supply, repair, service and calibration of Laboratory equipment, Industrial & process control equipment, Medical Laboratory Equipment

    Main Links

  • Home
  • Shop
  • Contact
  • Contact Us

  • 33 Western Road, Greendale, Harare
  • +263 8644 297 060
  • +263777271293